%global _empty_manifest_terminate_build 0 Name: python-adext Version: 0.4.2 Release: 1 Summary: AlarmDecoder extended License: MIT URL: https://github.com/ajschmidt8/adext Source0: https://mirrors.nju.edu.cn/pypi/web/packages/d2/95/dffa1a23232b725418a7579cb988d5245e588d677b3389bef3868d8dfbc8/adext-0.4.2.tar.gz BuildArch: noarch Requires: python3-alarmdecoder %description # adext `adext` is a small package that extends [alarmdecoder](https://github.com/nutechsoftware/alarmdecoder/) to include some additional methods for [Home Assistant](https://github.com/home-assistant/core). Specifically, the following methods have been added: - `arm_home` - `arm_away` - `arm_night` Each method accepts the arguments described below to determine which key sequences are used to arm a panel based on factors like panel brand and user config settings. ## Arguments: - **code**: (`None` or `str`) - the code used to arm a panel (i.e. `'1234'`) - **auto_bypass**: (`bool`) - for Honeywell only. set to `True` to prefix an arming sequence with ` + 6#` in order to automatically bypass any faulted zones. This will require a code to be entered even if `code_arm_required` is set to `false`." - **code_arm_required**: (`bool`) - set to `False` to enable arming without a code. see [Arming Key Sequences](#Arming-Key-Sequences) below. - **alt_night_mode**: (`bool`) - For Honeywell systems, set to `true` to enable *Night-Stay* mode instead of *Instant* mode for night arming. For DSC systems, set to `true` to enable *No-Entry* mode instead of *Stay* mode for night arming. For both systems, whenever this option is set to `true`, a code will be required for night arming **regardless of the `code_arm_required` setting.** See [Arming Key Sequences](#Arming-Key-Sequences) section below for more information. ## Arming Key Sequences The tables below show the key press sequences used for arming for the different panel brands and configuration setting combinations. ### Honeywell #### code_arm_required = true (default) | Mode | Key Sequence | | ------------------------------------------------------- | --------------------------- | | `alarm_arm_home` | `code` + `3` | | `alarm_arm_away` | `code` + `2` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `code` + `7` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `code` + `33` | #### code_arm_required = false | Mode | Key Sequence | | ------------------------------------------------------- | --------------------------- | | `alarm_arm_home` | `#3` | | `alarm_arm_away` | `#2` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `#7` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `code` + `33` | ### DSC #### code_arm_required = true (default) | Mode | Key Sequence | | ------------------------------------------------------- | --------------------------- | | `alarm_arm_home` | `code` | | `alarm_arm_away` | `code` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `code` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `*9` + `code` | #### code_arm_required = false
The `chr(4)` and `chr(5)` sequences below are equivalent to pressing the Stay and Away keypad keys respectively (as outlined in the AlarmDecoder documentation).
| Mode | Key Sequence | | ------------------------------------------------------- | ------------------------------- | | `alarm_arm_home` | `chr(4)` + `chr(4)` + `chr(4)` | | `alarm_arm_away` | `chr(5)` + `chr(5)` + `chr(5)` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `chr(4)` + `chr(4)` + `chr(4)` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `*9` + `code` | %package -n python3-adext Summary: AlarmDecoder extended Provides: python-adext BuildRequires: python3-devel BuildRequires: python3-setuptools BuildRequires: python3-pip %description -n python3-adext # adext `adext` is a small package that extends [alarmdecoder](https://github.com/nutechsoftware/alarmdecoder/) to include some additional methods for [Home Assistant](https://github.com/home-assistant/core). Specifically, the following methods have been added: - `arm_home` - `arm_away` - `arm_night` Each method accepts the arguments described below to determine which key sequences are used to arm a panel based on factors like panel brand and user config settings. ## Arguments: - **code**: (`None` or `str`) - the code used to arm a panel (i.e. `'1234'`) - **auto_bypass**: (`bool`) - for Honeywell only. set to `True` to prefix an arming sequence with ` + 6#` in order to automatically bypass any faulted zones. This will require a code to be entered even if `code_arm_required` is set to `false`." - **code_arm_required**: (`bool`) - set to `False` to enable arming without a code. see [Arming Key Sequences](#Arming-Key-Sequences) below. - **alt_night_mode**: (`bool`) - For Honeywell systems, set to `true` to enable *Night-Stay* mode instead of *Instant* mode for night arming. For DSC systems, set to `true` to enable *No-Entry* mode instead of *Stay* mode for night arming. For both systems, whenever this option is set to `true`, a code will be required for night arming **regardless of the `code_arm_required` setting.** See [Arming Key Sequences](#Arming-Key-Sequences) section below for more information. ## Arming Key Sequences The tables below show the key press sequences used for arming for the different panel brands and configuration setting combinations. ### Honeywell #### code_arm_required = true (default) | Mode | Key Sequence | | ------------------------------------------------------- | --------------------------- | | `alarm_arm_home` | `code` + `3` | | `alarm_arm_away` | `code` + `2` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `code` + `7` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `code` + `33` | #### code_arm_required = false | Mode | Key Sequence | | ------------------------------------------------------- | --------------------------- | | `alarm_arm_home` | `#3` | | `alarm_arm_away` | `#2` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `#7` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `code` + `33` | ### DSC #### code_arm_required = true (default) | Mode | Key Sequence | | ------------------------------------------------------- | --------------------------- | | `alarm_arm_home` | `code` | | `alarm_arm_away` | `code` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `code` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `*9` + `code` | #### code_arm_required = false
The `chr(4)` and `chr(5)` sequences below are equivalent to pressing the Stay and Away keypad keys respectively (as outlined in the AlarmDecoder documentation).
| Mode | Key Sequence | | ------------------------------------------------------- | ------------------------------- | | `alarm_arm_home` | `chr(4)` + `chr(4)` + `chr(4)` | | `alarm_arm_away` | `chr(5)` + `chr(5)` + `chr(5)` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `chr(4)` + `chr(4)` + `chr(4)` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `*9` + `code` | %package help Summary: Development documents and examples for adext Provides: python3-adext-doc %description help # adext `adext` is a small package that extends [alarmdecoder](https://github.com/nutechsoftware/alarmdecoder/) to include some additional methods for [Home Assistant](https://github.com/home-assistant/core). Specifically, the following methods have been added: - `arm_home` - `arm_away` - `arm_night` Each method accepts the arguments described below to determine which key sequences are used to arm a panel based on factors like panel brand and user config settings. ## Arguments: - **code**: (`None` or `str`) - the code used to arm a panel (i.e. `'1234'`) - **auto_bypass**: (`bool`) - for Honeywell only. set to `True` to prefix an arming sequence with ` + 6#` in order to automatically bypass any faulted zones. This will require a code to be entered even if `code_arm_required` is set to `false`." - **code_arm_required**: (`bool`) - set to `False` to enable arming without a code. see [Arming Key Sequences](#Arming-Key-Sequences) below. - **alt_night_mode**: (`bool`) - For Honeywell systems, set to `true` to enable *Night-Stay* mode instead of *Instant* mode for night arming. For DSC systems, set to `true` to enable *No-Entry* mode instead of *Stay* mode for night arming. For both systems, whenever this option is set to `true`, a code will be required for night arming **regardless of the `code_arm_required` setting.** See [Arming Key Sequences](#Arming-Key-Sequences) section below for more information. ## Arming Key Sequences The tables below show the key press sequences used for arming for the different panel brands and configuration setting combinations. ### Honeywell #### code_arm_required = true (default) | Mode | Key Sequence | | ------------------------------------------------------- | --------------------------- | | `alarm_arm_home` | `code` + `3` | | `alarm_arm_away` | `code` + `2` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `code` + `7` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `code` + `33` | #### code_arm_required = false | Mode | Key Sequence | | ------------------------------------------------------- | --------------------------- | | `alarm_arm_home` | `#3` | | `alarm_arm_away` | `#2` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `#7` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `code` + `33` | ### DSC #### code_arm_required = true (default) | Mode | Key Sequence | | ------------------------------------------------------- | --------------------------- | | `alarm_arm_home` | `code` | | `alarm_arm_away` | `code` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `code` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `*9` + `code` | #### code_arm_required = false
The `chr(4)` and `chr(5)` sequences below are equivalent to pressing the Stay and Away keypad keys respectively (as outlined in the AlarmDecoder documentation).
| Mode | Key Sequence | | ------------------------------------------------------- | ------------------------------- | | `alarm_arm_home` | `chr(4)` + `chr(4)` + `chr(4)` | | `alarm_arm_away` | `chr(5)` + `chr(5)` + `chr(5)` | | `alarm_arm_night` (`alt_night_mode` = `false`, default) | `chr(4)` + `chr(4)` + `chr(4)` | | `alarm_arm_night` (`alt_night_mode` = `true`) | `*9` + `code` | %prep %autosetup -n adext-0.4.2 %build %py3_build %install %py3_install install -d -m755 %{buildroot}/%{_pkgdocdir} if [ -d doc ]; then cp -arf doc %{buildroot}/%{_pkgdocdir}; fi if [ -d docs ]; then cp -arf docs %{buildroot}/%{_pkgdocdir}; fi if [ -d example ]; then cp -arf example %{buildroot}/%{_pkgdocdir}; fi if [ -d examples ]; then cp -arf examples %{buildroot}/%{_pkgdocdir}; fi pushd %{buildroot} if [ -d usr/lib ]; then find usr/lib -type f -printf "/%h/%f\n" >> filelist.lst fi if [ -d usr/lib64 ]; then find usr/lib64 -type f -printf "/%h/%f\n" >> filelist.lst fi if [ -d usr/bin ]; then find usr/bin -type f -printf "/%h/%f\n" >> filelist.lst fi if [ -d usr/sbin ]; then find usr/sbin -type f -printf "/%h/%f\n" >> filelist.lst fi touch doclist.lst if [ -d usr/share/man ]; then find usr/share/man -type f -printf "/%h/%f.gz\n" >> doclist.lst fi popd mv %{buildroot}/filelist.lst . mv %{buildroot}/doclist.lst . %files -n python3-adext -f filelist.lst %dir %{python3_sitelib}/* %files help -f doclist.lst %{_docdir}/* %changelog * Fri Apr 07 2023 Python_Bot - 0.4.2-1 - Package Spec generated